Cęgi prądowe 30A





Informacje o produkcie
Specifications
Electrical data | |
---|---|
Nominal current | 30 A AC peak or DC |
Measuring range (s) | 30 mA to 30 A DC (accurate) 5 mA to 30 A DC (usable) |
Overload capacity | 500 A for 60 s |
Output sensitivity | 100 mV/A |
Accuracy | ±(2% of reading ± 2 mA) |
Resolution | ± 1 mA DC after filtering |
di/dt tracking capability | > 20 A/µs |
Conductor position sensitivity | ± 1% relative to center |
Temperature coefficient | 0.1 x specified accuracy/°C (0 °C to 18 °C, 28 °C to 50 °C) |
Frequency range | DC to 20 kHz (–0.5 dB) |
Battery type | 9 V PP3, MN 1604, 6F22, 6LR61 |
Min. load impedance | 1 MΩ |
General data | |
---|---|
Max. conductor size | 19 mm diameter |
Output cable and connectors | 2 m long coax terminated with safety BNC connector |
Operating temperature | +5 °C to +40 °C |
Storage temperature (excluding battery) | –20°C to +70°C |
Humidity | 0 to 80 %RH |
Altitude | 0 to 2000 m |
Weight | 300 g |
Dimensions (H x W x D) | 200 mm x 72 mm x 38 mm |
Pollution degree | 2 |
Safety | EN 61010-1:2010 EN 61010-2-032:2012 |
EMC | EN 61326-1:2006 EN 61326-2-2:2006 |
Environmental | RoHS and WEEE compliant |